{"product_id":"panasonic-air-conditioning-u-14mf3e8-40-0-kw-ecoi-3-pipe-h-r-inv-o-d-r410a-3ph-415v-16329","title":"Panasonic Air Conditioning U-14MF3E8 40.0 kW ECOi 3 pipe H\/R Inv O\/D R410a 3ph 415V","description":"\u003ch2\u003ePanasonic Air Conditioning U-14MF3E8 40.0 kW ECOi 3 pipe H\/R Inv O\/D R410a 3ph 415V\u003c\/h2\u003e\u003cp\u003ePanasonic Air Conditioning U-14MF3E8 40.0 kW ECOi 3 pipe H\/R Inv O\/D R410a 3ph 415V is listed for TieDex store sale under Panasonic Air Conditioning VRF. The brand\/vendor is Panasonic Air Conditioning. This listing has been prepared with structured product information, clean import fields, image mapping, and SEO-ready content for online selling.\u003c\/p\u003e\u003ch3\u003eProduct Overview\u003c\/h3\u003e\u003cp\u003ePanasonic Air Conditioning U-14MF3E8 40.0 kW ECOi 3 pipe H\/R Inv O\/D R410a 3ph 415V Key Product Features: 8HP 10HP 12HP 14HP 16HP Outdoor Units U-8MF3E8 U-10MF3E8 U-12MF3E8 U-14MF3E8 U-16MF3E8 Voltage V 380 \/ 400 \/ 415 380 \/ 400 \/ 415 380 \/ 400 \/ 415 380 \/ 400 \/ 415 380 \/ 400 \/ 415 Power supply Phase Three Phase Three Phase Three Phase Three Phase Three Phase Frequency Hz 50 50 50 50 50 Starting current A 1,00 1,00 1,00 2,00 2,00 External static pressure (Max) Pa 80 80 80 80 80 Air volume m\/min 210 220 232 232 232 Sound pressure Normal mode dB(A) 54,00 57,00 60,00 61,00 62,00 Silent mode 1 \/ 2 dB(A) 51,00 \/ 49,00 54,00 \/ 52,00 57,00 \/ 55,00 58,00 \/ 56,00 59,00 \/ 57,00 Sound power Normal mode dB 76,00\u003c\/p\u003e\u003cp\u003e78,00 81,00 82,00 82,00 Dimension H x W x D mm 1842 x 1180 x 1000 1842 x 1180 x 1000 1842 x 1180 x 1000 1842 x 1180 x 1000 1842 x 1180 x 1000 Net weight kg 261 262 286 334 334 Liquid pipe Inch (mm) 3\/8 (9,52) \/ 1\/2 (12,70) 3\/8 (9,52) \/ 1\/2 (12,70) 1\/2 (12,70) \/ 5\/8 (15,88) 1\/2 (12,70) \/ 5\/8 (15,88) 1\/2 (12,70) \/ 5\/8 (15,88) Piping connections 3) Discharge pipe Inch (mm) 5\/8 (15,88) \/ 3\/4 (19,05) 3\/4 (19,05) \/ 7\/8 (22,22) 3\/4 (19,05) \/ 7\/8 (22,22) 7\/8 (22,22) \/ 1 (25,40) 7\/8 (22,22) \/ 1 (25,40) Suction pipe Inch (mm) 3\/4 (19,05) \/ 7\/8 (22,22) 7\/8 (22,22) \/ 1 (25,40) 1 (25,40) \/ 1-1\/8 (28,58) 1 (25,40) \/ 1-1\/8 (28,58) 1-1\/8(28,58)\/1-1\/4(31,75) Balance pipe Inch (mm) 1\/4 (6,35) 1\/4 (6,35) 1\/4 (6,35)\u003c\/p\u003e\u003cp\u003e1\/4 (6,35) 1\/4 (6,35) Refrigerant (R410A) kg \/ TCO Eq. 2 6,80 \/ 14,1984 6,80 \/ 14,1984 8,30 \/ 17,3304 8,30 \/ 17,3304 8,30 \/ 17,3304 Maximum allowable indoor \/ outdoor capacity ratio % 50 ~ 150 50 ~ 150 50 ~ 150 50 ~ 150 50 ~ 150 Cool Min ~ Max °C -10 ~ +52 -10 ~ +52 -10 ~ +52 -10 ~ +52 -10 ~ +52 Operating range Heat Min ~ Max °C -20 ~ +18 -20 ~ +18 -20 ~ +18 -20 ~ +18 -20 ~ +18 Simultaneous op. °C -10 ~ +24 -10 ~ +24 -10 ~ +24 -10 ~ +24 -10 ~ +24 Cooling capacity kW 22,40 28,00 33,50 40,00 45,00 EER 1) W\/W 5,11 4,72 3,91 3,70 3,49 SEER 2) W\/W 7,02 7,05 6,39 6,69 6,02 Running current cooling A 7,16 \/ 6,80\u003c\/p\u003e\u003cp\u003e\/ 6,55 9,90 \/ 9,41 \/ 9,07 3,19 \/ 13,20 \/ 12,70 18,20 \/ 17,30 \/ 16,70 21,30 \/ 20,20 \/ 19,50 Input power cooling kW 4,38 5,93 8,57 10,80 12,90 Heating capacity kW 25,00 31,50 37,50 45,00 50,00 COP 1) W\/W 5,25 5,17 4,51 4,21 4,17 SCOP 2) W\/W 4,85 4,25 4,27 4,13 3,81 Running current heating A 7,78 \/ 7,39 \/ 7,12 10,20 \/ 9,66 \/ 9,31 13,40 \/ 12,80 \/ 12,30 18,10 \/ 17,20 \/ 16,50 20,00 \/ 19,00 \/ 18,30 Input power heating kW 4,76 6,09 8,32 10,70 12,00 3-Pipe control box kit CZ-P456HR3 4 ports 3 pipe box (up to 5,60kW) CZ-P56HR3 Solenoid valve kit (up to 5,60kW) CZ-CAPE2 3-Pipe control PCB KIT-P160HR3 3-Pipe control Solenoid valve kit (from 5,6 to 10,60kW) CZ-P160HR3 Solenoid valve kit (up to 16,00kW) CZ-CAPE2 3-Pipe control PCB CZ-P656HR3 6\u003c\/p\u003e\u003cp\u003eports 3 pipe box (up to 5,60kW) CZ-P856HR3 8 ports 3 pipe box (up to 5,60kW) CZ-P4160HR3 4 ports 3 pipe box (up to 16,00kW) Solenoid valve kit KIT-P56HR3 3-Pipe control Solenoid valve kit (up to 5,60kW) PDF Data: These air conditioning units must be installed by an F-Gas qualified engineer. We can install the unit for you using our F-Gas Certified Engineers. Please note if you do not select our installation service we will not ship the unit until we have obtained evidence from you that you will have the unit installed by an F-Gas qualified engineer. This is a requirement of the Article 11 (5) EC\/517\/2014 on fluorinated greenhouse gases and The Fluorinated Greenhouse Gases Regulations 2015.\u003c\/p\u003e\u003ch3\u003eKey Details\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eBrand \/ Vendor: Panasonic Air Conditioning\u003c\/li\u003e\n\u003cli\u003eProduct SKU: U-14MF3E8\u003c\/li\u003e\n\u003cli\u003eMPN \/ Model: U-14MF3E8\u003c\/li\u003e\n\u003cli\u003eCategory: Panasonic Air Conditioning VRF\u003c\/li\u003e\n\u003cli\u003eParent Category: Panasonic Air Conditioning\u003c\/li\u003e\n\u003cli\u003eCondition: New\u003c\/li\u003e\n\u003cli\u003eAvailability: InStock\u003c\/li\u003e\n\u003cli\u003eTieDex UK\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Panasonic Air Conditioning","offers":[{"title":"Default Title","offer_id":56307446350203,"sku":"OASU-14MF3E8","price":11464.04,"currency_code":"GBP","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0283\/5408\/4963\/files\/panasonic-air-conditioning-u-14mf3e8-40.0-kw-ecoi-3-pipe-h-r-inv-o-d-r410a-3ph-415v-16329-p.jpg?v=1782161574","url":"https:\/\/tiedex.co.uk\/de\/products\/panasonic-air-conditioning-u-14mf3e8-40-0-kw-ecoi-3-pipe-h-r-inv-o-d-r410a-3ph-415v-16329","provider":"TieDex","version":"1.0","type":"link"}