{"product_id":"combat-elg235-natural-gas-and-lpg-fixed-elite-cabinet-heater-236kw-800000btu-415v-50hz-11822","title":"Combat ELG235 Natural Gas And LPG Fixed Elite Cabinet Heater 236Kw\/800000Btu 415V~50Hz","description":"\u003ch2\u003eCombat ELG235 Natural Gas And LPG Fixed Elite Cabinet Heater 236Kw\/800000Btu 415V~50Hz\u003c\/h2\u003e\u003cp\u003eCombat ELG235 Natural Gas And LPG Fixed Elite Cabinet Heater 236Kw\/800000Btu 415V~50Hz is listed for TieDex store sale under Floor Standing Cabinet Heater. The brand\/vendor is Combat. This listing has been prepared with structured product information, clean import fields, image mapping, and SEO-ready content for online selling.\u003c\/p\u003e\u003ch3\u003eProduct Overview\u003c\/h3\u003e\u003cp\u003eCombat ELG235 Natural Gas And LPG Fixed Elite Cabinet Heater 236Kw\/800000Btu 415V~50Hz FOR HEATING LARGE PREMISES WITH MINIMUM INSTALLATION REQUIREMENTS Running on natural gas or LPG, the fixed Combat ELG space heater range are the most functional and efficient alternative to traditional heating plants, also as a solution for intermittent or occasional use. Heating power, flexible use and low running costs make them ideal for heating large spaces such as industrial areas, large sheds, workshops, warehouses, laboratories, showrooms, supermarkets, religious buildings, gyms and tension structures. Where there is a need for the heater to be connected to fresh air or air from an adjacent area for its intake of distribution air, inlet duct connections can be provided. For all oil fired heaters, an oil line connection kit comprising of a gate valve, spring operated fire valve, oil filter and connecting\u003c\/p\u003e\u003cp\u003enipples are supplied for installation on site. Key Product Features: • Combat Elite Cabinet Heaters are fitted witha packaged burner, utilising two stage technology. • Gas options Natural Gas (G20) (standard) and LPG G31 (upon request). • Each heater is supplied with the Combat NRG Control, fitted to the heater and pre-wired. • Electric board • Reduced Flue Size 130mm with self-sealing spigot push in • Centrifugal fan • Air inlet grills • Where there is a need for the heater to be connected to fresh air or air from an adjacent area for its intake of distribution air, inlet duct connections can be provided. • Body thermo-acoustic insulation and safe low surface temperature • Stainless steel combustion chamber with aerodynamic shape • High efficiency heat exchanger • New sleek distribution head shape • On request bio-gas feeding Technical Data:\u003c\/p\u003e\u003cp\u003eModel Unit 75 105 135 185 235 'A' Width mm 723 857 857 1,016 1,016 'B' Depth cabinet only mm 860 860 1015 1676 1676 'C' Height cabinet only mm 1,734 1,925 1,925 1,925 1,925 'D' Depth overall mm 1,370 1,380 1,490 2,255 2,255 'E' Height incl.heads mm 2,038 2,230 2,230 2,230 2,230 'F' Left\/Right hand air inlet spigot - height mm 781 781 940 1600 1600 'G' Left\/Right hand air inlet spigot - Depth mm 457 457 560 560 560 'H' Rear air inlet spigot - Depth mm 648 781 781 N\/A N\/A 'J' Rear air inlet spigot - height mm 361 446 446 N\/A N\/A Weight kg 200 245 270 440 440 Flue Diameter mm 130 130 130 130 130 Flue Length m 8 8 8 8 8 Heater Clearances to Combustibles (mm) To Side of Heater To\u003c\/p\u003e\u003cp\u003eRear of Heater To Front of Heater For Air Distribution 600 600 2,000 4,000 Model Stage Unit 75 105 135 185 235 Maximum Heater Input- Gross High Fire [kW] 93.0 128.0 162.0 225.0 285.0 Low Fire 47.0 65.0 81.0 112.0 141.0 Net Heat Input High Fire [kW] 83.8 115.3 146.0 202.7 256.8 Low Fire 42.3 58.6 73.0 100.9 127.0 Maximum Heat Output High Fire [kW] 76.7 104.3 133.4 186.5 236.8 Low Fire 40.5 56.3 70.0 95.9 112.5 Maximum Gas Rate Natural (G20) High Fire [m3\/h] 8.4 11.6 14.3 20.3 25.7 Low Fire 4.3 5.8 7.2 10.1 12.6 Maximum Gas Rate LPG Propane (G31) High Fire [m3\/h] 3.5 4.8 5.9 8.5 10.6 Low Fire 1.8 2.4 3.0 4.2 5.2 Inlet Pressure Natural Gas (G20) [mbar] 20 20 20 20 20 Minimum 17 mbar Maximum 25 mbar Inlet Pressure LPG Propane Gas\u003c\/p\u003e\u003cp\u003e(G31) [mbar] 37 37 37 37 37 Minimum 25 mbar Maximum 45 mbar Gas Connection Inches BSP 3\/4 1 1\/4 General Data Model Unit 75 105 135 185 235 Electrical Supply* 230v 50Hz 1 Phase 400v 50Hz 3 Phase Main Fan Motor Type Direct Drive Belt Drive Motor Size kW 0.75 2.2 1.5 2.2 Start Current [A] 11.5 9.0 10 10.0 24.0 Run Current [A] 6.5 5.0 3.7 3.7 5.1 Airflow - Free Blowing [m3\/h] 5,200 8,600 8,600 11,200 14,200 PDF Data Sheet: ​​​​​​​\u003c\/p\u003e\u003ch3\u003eKey Details\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eBrand \/ Vendor: Combat\u003c\/li\u003e\n\u003cli\u003eProduct SKU: ELG235\u003c\/li\u003e\n\u003cli\u003eMPN \/ Model: ELG235\u003c\/li\u003e\n\u003cli\u003eCategory: Floor Standing Cabinet Heater\u003c\/li\u003e\n\u003cli\u003eParent Category: Heating\u003c\/li\u003e\n\u003cli\u003eCondition: New\u003c\/li\u003e\n\u003cli\u003eAvailability: InStock\u003c\/li\u003e\n\u003cli\u003eTieDex UK\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Combat","offers":[{"title":"Default Title","offer_id":56306357928315,"sku":"ELG235","price":10420.4,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0283\/5408\/4963\/files\/combat-elg235-natural-gas-and-lpg-fixed-elite-cabinet-heater-236kw-800000btu-415v-50hz-11822-p.jpg?v=1782057889","url":"https:\/\/tiedex.co.uk\/es\/products\/combat-elg235-natural-gas-and-lpg-fixed-elite-cabinet-heater-236kw-800000btu-415v-50hz-11822","provider":"TieDex","version":"1.0","type":"link"}