{"product_id":"daikin-air-conditioning-daikin-heat-pump-air-curtain-cyqs200dk100-bn-sn-10-kw-34000btu-230v-50hz-4390","title":"Daikin Air Conditioning Daikin Heat Pump Air Curtain CYQS200DK100*BN\/*SN 10 kW \/ 34000Btu 230V~50hZ","description":"\u003ch2\u003eDaikin Air Conditioning Daikin Heat Pump Air Curtain CYQS200DK100*BN\/*SN 10 kW \/ 34000Btu 230V~50hZ\u003c\/h2\u003e\u003cp\u003eDaikin Air Conditioning Daikin Heat Pump Air Curtain CYQS200DK100*BN\/*SN 10 kW \/ 34000Btu 230V~50hZ is listed for TieDex store sale under Daikin Air Curtains. The brand\/vendor is Daikin Air Conditioning. This listing has been prepared with structured product information, clean import fields, image mapping, and SEO-ready content for online selling.\u003c\/p\u003e\u003ch3\u003eProduct Overview\u003c\/h3\u003e\u003cp\u003eDaikin Heat Pump Air Curtain CYQS200DK100*BN\/*SN 10 kW \/ 34000Btu 230V~50hZ Air Curtains for light commercial applications. Daikin standard air curtains are the ideal solution for retailers and consultants to combat the issue of climate seperatiom across their outlet or office doorway. Using a combination of rectifier technology, optimised air velocity and temperature control, they deliver greater comfort to staff and customers alike, all year roumd, in all weathers. In conjunction with Biddle, Daikin now offer the best air curtain to the market, coupling the benefits of the Biddle air curtain technology with the benefits of the Daikin heat pump inverter technology. Technical Specifications Evaporator Technical Specifications CYQS200DK100*BN\/*SN Heating capacity Installation level B speed 2 kW 9.2 speed 3 kW 11.6 Delta T inlet = room temperature speed 2 K 17 speed 3 K 15 Power Input (50Hz) Fan only\u003c\/p\u003e\u003cp\u003ekW 0.46 Heating kW 0.46 Maximum door width m 2 Maximum door height Favorable conditions m 2.3 Normal conditions m 2.15 Unfavorable conditions m 2 Dimensions Height Unit F mm 270 Unit C mm 270 Unit R mm 270 Width Unit F mm 2,000 Unit C mm 2,000 Unit R mm 2,048 Depth Unit F mm 590 Unit C mm 821 Unit R mm 561 Packed unit Height mm 760 Width mm 2,130 Depth mm 680 Weight Unit F kg 83 Unit C kg 102 Unit R kg 108 Packed unit F kg 115 Packed unit C kg 139 Packed unit R kg 145 Casing Colour BN:RAL9010 SN:RAL 9006 Material Electrogalvanised sheet steel Required Ceiling Void mm 420 Fan - Air flow rate - Heating Installation level B speed 2 m³\/h 1,646 speed 3 m³\/h 2,328 Refrigerant Type R-410A Control\u003c\/p\u003e\u003cp\u003eElectronic expansion valve Sound pressure level - Heating Installation level B speed 2 dBA 40 speed 3 dBA 50 Piping connections Liquid (OD) Diameter (OD) mm 9.52 Gas Diameter (OD) mm 16 Air Filter Vacuum cleanable filter G1 Required accessories Daikin wired remote control (BRC1E51A or BRC1D52) Notes Favorable conditions: covered shopping mall or revolving-door entrance. Normal conditions: little direct wind, no opposite open doors, building with ground floor only. Unfavorable conditions: location at a corner or square, multiple floors and\/or open stairway. Pipe work and electrical connections are on top of the unit Sound pressure level (at 3m) Installation level B: standard setting, refer to the databook or installation manual for more information (only one installation level available) *F = Free Hnging, C = Cassette, R = Recessed. Technical Specifications Condenser OUTDOOR UNIT ERQ100AV1 ERQ125AV1 capacity range hP 4\u003c\/p\u003e\u003cp\u003e5 cooling capacity nom. kW 11.2 (1) 14.0 (1) heating capacity nom. kW 12.5 (2) 16.0 (2) capacity control cooling min.\/max. % 24\/100 cooling nom. kW - Power input heating nom. kW - EER 3.99 (1) cOP 4.56 (2) 4.15 (2) colour Daikin White casing material Painted galvanized steel plate Dimensions unit heightxwidthxdepth mm 1,345x900x320 Weight unit kg 120 rows quantity 2 heat exchanger fin pitch mm 2 face area m² 1.131 stages quantity 60 fin type Non-symmetric waffle louvre type Propeller fan Fan air flow rate cooling nom. m³\/min 106 heating nom. m³\/min 102 105 model Brushless Dc motor Fan motor drive Direct drive Sound power level cooling nom. dBA 66 67 Sound pressure level cooling nom. dBA 50 51 heating nom. dBA 52 53 compressor model JT100G-VDL type hermetically sealed scroll compressor cooling min.~ max. °cDB -5~ 46\u003c\/p\u003e\u003cp\u003eOperation range heating min.~max. °cWB -20~15.5 Enterning air temperature on AhU heat exchanger cooling min.~ max. °cDB -14cWB~25cWB heating min.~max. °cWB 10cWB~27cWB type R-410A Refrigerant charge kg 4 control Expansion valve (electronic type) type Daphne FVc68D Refrigerant oil charged volume l 1.5 liquid type\/OD mm Flare connection\/9.52 Piping connections gas type\/OD mm Flare connection\/15.9 drain quantity\/OD mm 3\/26x3 heat insulation Both liquid and gas pipes Safety devices item 01\/02\/03\/04 high pressure switch\/Fan motor thermal protection\/Inverter overload protector\/Pc board fuse Power supply phase\/frequency\/voltage hz\/V 1N~\/50\/220-440 Electrical Specifications Electrical Specifications CQM100DK80 CYQM150DK80 CYQM200DK100 CYQM250DK140 Power Supply Frequency Hz 50 Voltage V 230 Voltage range Min. V 240 Current (50Hz) Maximum fuse amps (MFA) A 16\u003c\/p\u003e\u003ch3\u003eKey Details\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eBrand \/ Vendor: Daikin Air Conditioning\u003c\/li\u003e\n\u003cli\u003eProduct SKU: CYQS200DK100\u003c\/li\u003e\n\u003cli\u003eMPN \/ Model: CYQS200DK100\u003c\/li\u003e\n\u003cli\u003eCategory: Daikin Air Curtains\u003c\/li\u003e\n\u003cli\u003eParent Category: Commercial Heat Pump Air Curtains\u003c\/li\u003e\n\u003cli\u003eCondition: New\u003c\/li\u003e\n\u003cli\u003eAvailability: InStock\u003c\/li\u003e\n\u003cli\u003eTieDex UK\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Daikin Air Conditioning","offers":[{"title":"Default Title","offer_id":56306327912827,"sku":"CYQS200DK100","price":6421.46,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0283\/5408\/4963\/files\/daikin-heat-pump-air-curtain-cyqs200dk100-bn-sn-10-kw-34000btu-230v-50hz-4390-p.jpg?v=1782056173","url":"https:\/\/tiedex.co.uk\/es\/products\/daikin-air-conditioning-daikin-heat-pump-air-curtain-cyqs200dk100-bn-sn-10-kw-34000btu-230v-50hz-4390","provider":"TieDex","version":"1.0","type":"link"}