{"product_id":"daikin-air-conditioning-fua71a-under-ceiling-cassette-7kw-24000btu-a-r32-240v-50hz-3828","title":"Daikin Air Conditioning FUA71A Under Ceiling Cassette 7Kw\/24000Btu A+ R32 240V~50Hz","description":"\u003ch2\u003eDaikin Air Conditioning FUA71A Under Ceiling Cassette 7Kw\/24000Btu A+ R32 240V~50Hz\u003c\/h2\u003e\u003cp\u003eDaikin Air Conditioning FUA71A Under Ceiling Cassette 7Kw\/24000Btu A+ R32 240V~50Hz is listed for TieDex store sale under Daikin Air Conditioning Under Ceiling Cassette Inverter Heat Pump FUA A+. The brand\/vendor is Daikin Air Conditioning. This listing has been prepared with structured product information, clean import fields, image mapping, and SEO-ready content for online selling.\u003c\/p\u003e\u003ch3\u003eProduct Overview\u003c\/h3\u003e\u003cp\u003eA+ Energy rated product Includes: 1 x Daikin RZASG71M2V1 Outdoor unit R32 1 x Daikin FUA71A Under Ceiling Cassette R32 1 x Daikin Remote Controller Hard Wired Daikin’s Under Ceiling Cassette is a unique product, a 4 way blow system that can be installed under the ceiling in rooms that have solid ceilings or narrow voids that may prevent a traditional cassette being installed. Under Ceiling Cassette Seasonal Smart. The Under Ceiling Cassette exceeds Energy Related Products Directive minimum efficiency standards for Seasonal Efficiency, combining industry leading efficiencies with smart looks and functionality to suit office and retail applications. The re-designed profile of the unit means it is less obtrusive when installed. Air discharge louvres close completely when the unit is not operating, adding to the aesthetic. Energy savings can be made using the remote controller which gives control over\u003c\/p\u003e\u003cp\u003eset-point ranges and day-to-day use of controls. This can give occupants some flexibility over room conditions without compromising energy usage. Energy efficiencies can be improved by utilising the selectable evaporating and condensing temperature option, making the Seasonal Smart Under Ceiling Cassette the ideal solution for energy conscious building managers. Product Key Feature's: • High SCoP • High Air movement volume • Fixed wall mounted controller • Slim construction • Pipe runs up to 50 meters • Low noise levels • Back-up switch for loss of controller • Cold draft prevention on heat pump start up • Fault diagnosis • Auto re-start after power interruption • PRE-CHARGED WITH REFRIGERANT for up to 30 metres pipe length Product Technical Data: Power source 1 ph 240V Type Inverter controlled COOLING (nominal) max. kW 6.5 \/ 22000 BTU HEATING (nominal) max. kW 8.0 \/\u003c\/p\u003e\u003cp\u003e2700 0 BTU UK Cooling (max) kW 4.5 UK Sensible Cooling kW 4.5 E.E.R. Energy label in heating A+ Energy label in cooling A+ ECA - Yes INDOOR UNIT : Indoor Units Single Phase FUA71A C apacity UK T otal C ooling kW 7.76 UK Sensible C ooling kW 5.32 Nominal C ooling kW 6.80 Nominal He a ting kW 7.50 Seasonal Efficien c y (EN14825) C OOLING Ene r gy Label A+ P desi g n kW 6.80 SEER 6.50 A nnual Ene r gy C onsumption k Wh 367 Seasonal Efficien c y (EN14825) HE A TING Ene r gy Label A+ P desi g n kW 7.60 S C OP 4.20 A nnual Ene r gy C onsumption k Wh 2534 Nominal Efficien c y EER \/ C OP 4.05 \/ 4.08 Ene r gy Label A\u003c\/p\u003e\u003cp\u003e\/ A A nnual Ene r gy C onsumption k Wh 840 ir F l o w R a t e (C ooling) H igh \/ Nom \/ L o w m3\/sec 0.383 \/ 0.325 \/ 1.933 Dimensions Heig h t mm 198 W idth mm 950 Depth mm 950 W eig h t kg 25 Sound P r essu r e (C ooling) H igh \/ Nom \/ L o w dBA 41 \/ 38 \/ 35 Sound P o w er dBA 59 Model RZASG71M2V1 Casing Colour Ivory white Material Painted galvanized steel plate Dimensions Unit Height mm 770 Width mm 900 Depth mm 320 Packed unit Height mm 900 Width mm 980 Depth mm 420 Weight Unit kg 60 Packed unit kg 64 Packing Weight kg 4 Heat exchanger Fin Type WF fin Treatment Anti-corrosion treatment (PE)\u003c\/p\u003e\u003cp\u003eFan Type Propeller Discharge direction Horizontal Quantity 1 Air flow rate Cooling Nom. m³\/min 56 Heating Nom. m³\/min 50 Partial m³\/min Fan motor Quantity 1 Model Brushless DC motor Output W 94 Drive Direct drive Compressor Quantity 1 Type Hermetically sealed swing compressor Operation range Cooling Ambient Min. °CDB 46 Heating Ambient Min. °CWB 15.5 Sound power level Cooling dBA 65 Heating dBA Sound pressure level Cooling Nom. dBA 47 Refrigerant Type R-32 Charge kg 2.45 Charge TCO2Eq 1.65 Control Expansion valve (electronic type) GWP 675 Circuits Quantity 1 Refrigerant oil Type FW68DA Charged volume l 0.90 Piping connections Liquid Quantity 1 Type Flare connection OD mm 9.52 Gas Quantity 1 Type Flare connection OD mm 15.9 Drain Quantity 3 Type Hole OD mm 26 Piping length OU - IU Min. m 50 System Equivalent m 70 Chargeless m 30\u003c\/p\u003e\u003cp\u003eAdditional refrigerant charge kg\/m See installation manual Level difference IU - OU Max. m 0.5 Heat insulation Both liquid and gas pipes Defrost method Reversed cycle Defrost control Sensor for outdoor heat exchanger temperature Capacity control Method Inverter controlled PED Category Category II Safety devices Item 01 High pressure switch 02 Low pressure switch 03 Fan driver overload protector 04 Fuse 05 Compressor motor thermal protector Standard Accessories Tie-wraps 2 Installation manual 1 Refrigerant label for F-gas regulation 1 General safety precautions 1 LOT10 Energy Label 1 Peel off F-gas label 1 Power supply Name V1 Phase 1~ Frequency Hz 50 Voltage V 220-240 Voltage range Min. V 264 Current Zmax List Complies to EN61000-3-11 Minimum Ssc value kVa Equipment complying with EN \/ IEC 61000-3-12, See note 2, See note 3 Wiring connections For power supply Remark See installation\u003c\/p\u003e\u003cp\u003emanual outdoor unit For connection with indoor Remark See installation manual outdoor unit Power supply intake See installation manual outdoor unit Current - 50Hz Maximum fuse amps (MFA) A 20 Notes (1) - According to ENER Lot 21 (2) - European\/international technical standard setting the limits for harmonic currents produced by equipment connected to public low-voltage system with input current larger than 16A and ≤ 75A per phase. (3) - Ssc: Short-circuit power (4) - European\/international technical standard setting the limits for harmonic currents produced by equipment connected to public low-voltage system with input current ≤ 16A per phase. PDF Data: These air conditioning units must be installed by an F-Gas qualified engineer. We can install the unit for you using our F-Gas Certified Engineers. Please note if you do not select our installation service we will not ship the\u003c\/p\u003e\u003cp\u003eunit until we have obtained evidence from you that you will have the unit installed by an F-Gas qualified engineer. This is a requirement of the Article 11 (5) EC\/517\/2014 on fluorinated greenhouse gases and The Fluorinated Greenhouse Gases Regulations 2015.\u003c\/p\u003e\u003ch3\u003eKey Details\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eBrand \/ Vendor: Daikin Air Conditioning\u003c\/li\u003e\n\u003cli\u003eProduct SKU: FUA71A\u003c\/li\u003e\n\u003cli\u003eMPN \/ Model: FUA71A\u003c\/li\u003e\n\u003cli\u003eCategory: Daikin Air Conditioning Under Ceiling Cassette Inverter Heat Pump FUA A+\u003c\/li\u003e\n\u003cli\u003eParent Category: Daikin Air Conditioning\u003c\/li\u003e\n\u003cli\u003eCondition: New\u003c\/li\u003e\n\u003cli\u003eAvailability: InStock\u003c\/li\u003e\n\u003cli\u003eTieDex UK\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Daikin Air Conditioning","offers":[{"title":"Default Title","offer_id":56306325848443,"sku":"FUA71A","price":3766.89,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0283\/5408\/4963\/files\/daikin-air-conditioning-fua71a-under-ceiling-cassette-7kw-24000btu-a-r32-240v-50hz-3828-p.jpg?v=1782056028","url":"https:\/\/tiedex.co.uk\/es\/products\/daikin-air-conditioning-fua71a-under-ceiling-cassette-7kw-24000btu-a-r32-240v-50hz-3828","provider":"TieDex","version":"1.0","type":"link"}