{"product_id":"daikin-air-conditioning-rooftop-packaged-uatya70bbay1-heat-pump-70kw-238000btu-415v-50hz-14742","title":"Daikin Air Conditioning Rooftop Packaged UATYA70BBAY1 Heat Pump 70Kw\/238000Btu 415V~50Hz","description":"\u003ch2\u003eDaikin Air Conditioning Rooftop Packaged UATYA70BBAY1 Heat Pump 70Kw\/238000Btu 415V~50Hz\u003c\/h2\u003e\u003cp\u003eDaikin Air Conditioning Rooftop Packaged UATYA70BBAY1 Heat Pump 70Kw\/238000Btu 415V~50Hz is listed for TieDex store sale under Daikin Air Conditioning Rooftop Packaged UATYA-BBAY1 Heat Pump Base Model. The brand\/vendor is Daikin Air Conditioning. This listing has been prepared with structured product information, clean import fields, image mapping, and SEO-ready content for online selling.\u003c\/p\u003e\u003ch3\u003eProduct Overview\u003c\/h3\u003e\u003cp\u003eThis package includes the UATYA complete system assembled and delivery to site with crane curb side delivery, the unit is delivered via a hiab truck with a 6 metre reach. The Daikin packaged rooftop UATYA cooling and heating air conditioning system (now in R32 2021) combines the economy and simplicity of split system technology with the flexibility of ducted air distribution. The compressor, evaporator and condenser units are combined into a fully integrated package which can supply efficient cooling or heating, all through conventional ducting and air grilles located throughout the building. It has a wide operating range, flat top unit design which allows maximum use of warehouse and container space. Easy to install ‘plug and play’ concept plus single installation configuration, no additional piping is required since indoor and outdoor sides are pre-connected. Daikin UATYA convertible return and supply\u003c\/p\u003e\u003cp\u003eair: fan can be mounted in two directions and is factory pre-charged refrigerant ensures clean and efficient operation. Belt driven fan enables air volume and static pressure to be adjusted as required. Anti-corrosion treated coil. Supplied with high efficiency and reliable scroll compressors, optimised heat exchangers and high-performing fans, the rooftop UATYA series are designed to ensure a high energy efficiency and reduced consumption. ​ Rooftop for Retail, Warehouses \u0026amp; Industry: For building managers and engineers, warehouses or industrial applications can pose serious HVAC challenges because of their size and unique design. Daikin rooftops provide the solution: Indoor\/outdoor packaged unit and factory charged refrigerant provide cost-effective installation. High ESP up to 800Pa allows extensive duct-work to evenly distribute the air across a large space. Scroll compressor and free cooling ensure highly efficient 24\/7 operation. Clogged filter alarm indicates when filter\u003c\/p\u003e\u003cp\u003eneeds cleaning, ensuring optimum operation and minimised energy consumption. Retail \u0026amp; department stores need challenging design because of limited space and complex building structure, containing different floors and spaces. Daikin rooftops provide the solution: Duct-work can be connected flexibly (front, left, right, bottom) to optimise installation space High efficiency EC plug fans are maintenance free, limiting the downtime of the system for maintenance. Extraction damper and fan ensure there is no overpressure in the building and air circulation is optimised. High indoor air quality can be guaranteed thanks to integrated fresh air provision and multiple air filtration possibilities. Key Product Features: Heat Pump heating and cooling R32 refrigerant 3 phase power supply ON\/OFF Switch \u0026amp; Auto-restart Temperature Setting (16°C to 30°C) Operation Modes: - Cooling Only: Cool \/ Dry \/ Fan Heat Pump: Auto \/ Cool \/ Dry \/ Heat\u003c\/p\u003e\u003cp\u003e\/ Fan Fan Speed Selection \u0026amp; Air Swing Timer (setting range between 1 to 15 hours) Sleep Mode (only possible under ‘cool’ or ‘heat’ mode operation) Technical Data: Model: UATYA-BBAY1 25 30 40 50 60 70 80 90 100 110 120 140 150 160 180 190 Cooling capacity Nom. kW 25.8 33.4 38.7 45.7 58.8 65.3 74.8 89.8 95.8 108.9 115 133.4 144.7 154.6 171.9 187 Heating capacity Nom. kW 25.3 31.1 36.3 46.2 55.1 64.9 68.5 84.2 92.8 101.5 108 123.1 136.4 147.1 157.1 176.9 EER 2.83 3.09 3.06 2.96 3.12 2.92 3.09 3.06 2.97 2.99 2.91 3.14 3.02 3.05 3.07 2.97 COP 3.22 3.31 3.26 3.24 3.25 3.21 3.37 3.22 3.2 3.35 3.25 3.44 3.33 3.26 3.33 3.27 Space cooling Capacity Pdesign kW 25.8 33.4 38.7 45.7 58.8 65.3 74.8 89.8 95.8 108.9 115 133.4 144.7 154.6 171.9\u003c\/p\u003e\u003cp\u003e187 SEER 4.62 4.89 5.48 5.34 5.5 4.53 5.56 5.47 5.17 5.29 5.15 4.38 4.26 4.27 4.15 4.08 ηs,c % 181.6 192.56 216.12 210.48 217.08 178.08 219.36 215.8 203.72 208.64 203.04 172.08 167.2 167.6 162.84 160.24 Space heating (Average climate) Capacity Pdesign kW 25.3 31.1 36.3 46.2 55.1 64.9 68.5 84.2 92.8 101.5 108 123.1 136.4 147.1 157.1 176.9 SCOP\/A 3.35 3.38 3.67 3.65 3.47 3.41 3.7 3.65 3.62 3.56 3.53 3.39 3.36 3.34 3.31 3.34 ηs,h % 131 132.16 143.84 142.96 135.6 133.52 145.16 142.96 141.64 139.28 138.28 132.52 131.44 130.76 129.52 130.56 Evaporator Supply side Air discharge direction Frontal, Left Bottom, Right, Left Fan Air flow rate m³\/h 4,500 5,800 7,500 9,000 11,000 13,000 14,500 16,500 18,000 19,800 21,600 25,000 26,500 28,000 30,500 31,500 Nominal ESP Pa 300 Return side Air intake direction Rear Thermodynamic heat recovery No\u003c\/p\u003e\u003cp\u003eFresh air Standard No Condenser Air flow rate Cooling m³\/h 15,725 16,038 16,374 16,341 31,183 32,203 35,774 37,285 36,195 38,143 36,865 70,704 72,395 67,733 70,200 72,005 Refrigerant Type R-32 GWP 675 Charge tCO2Eq 4.725 6.750 8.100 10.125 12.150 15.525 16.200 18.900 20.250 24.300 25.650 31.050 33.750 kg 7 10 12 15 18 23 24 28 30 36 38 46 50 Dimensions Unit Height mm 1,924 2,374 1,924 2,374 Width mm 2,250 Depth mm 2,427 4,317 5,117 Weight Unit kg 1,023 1,077 1,174 1,193 1,739 1,841 2,028 2,086 2,154 2,242 2,252 2,690 2,696 2,738 2,792 2,872 Casing Colour RAL 7035 Sound pressure level Cooling dBA TBC 66 68 67.3 69 68.1 72.6 68.7 69.9 70.6 74.2 68.3 68.3 68.7 69.1 70 Sound power level Cooling dBA TBC 84.3 86.8 86.1 88.5 87.5 92.5 88.6 89.8 90.5 94.1 88.6 88.6 89 89.3\u003c\/p\u003e\u003cp\u003e90.2 Operation range Cooling Min. °CDB 26 Power supply Phase 3~ Frequency Hz 50 Voltage V 400 Recommended fuses A 25 40 50 63 80 100 160 200 Field applied accessories for Made-To-Stock units: Ac cessories MTS - BASE series - UATYA-BBAY1 25-30 40-50 60-70 80-120 140-190 Air treatment Filter ISO Coarse 75% (G4) 2x UATYAC75A + 2x UATYAC75B (Standard) 3x UATYAC75A + 3x UATYAC75B (Standard) 6x UATYAC75B (Standard) 12x UATYAC75C (Standard) 12x UATYAC75C (Standard) Filter ISO ePM10 50% (M5\/F5) 2x UATY- AEPM1050A + 2x UATY- AEPM1050B 3x UATY- AEPM1050A + 3x UATY- AEPM1050B 3x UATY- AEPM1050B 12x UATYAEP- M1050C 12x UATYAEP- M1050C Filter ISO ePM10 70% (M6) 2x UATYAEP- M1070A + 2x UATY- AEPM1070B 3x UATYAEP- M1070A + 3x UATY- AEPM1070B 6x UATY- AEPM1070B 12x UATYAEP- M1070C 12x UATYAEP- M1070C Rigid bag filter ISO ePM1 50% (F7) 2x UATYAEP-\u003c\/p\u003e\u003cp\u003eM150A + 2x UATY- AEPM150B 3x UATYAEP- M150A + 3x UATY- AEPM150B 6x UATY- AEPM150B 12x UATYAEP- M150C 12x UATYAEP- M150C Rigid bag filter ISO ePM1 85% (F9) 2x UATYAEP- M185A + 2x UATY- AEPM185B 3x UATYAEP- M185A + 3x UATY- AEPM185B 6x UATYAEPM185B 12x UATYAEP- M185C 12x UATYAEP- M185C Control UATYACO2P - Duct air quality CO2 probe • • • • • UATYACAP - Constant air pressure control airflow transducer • • • • • UATYAWRC - Remote touch screen wired remote controller • • • • • UATYARRP - Room temperature return probe (incl. housing) • • • • • UATYASA - Fire and smoke alarm • • • • • Other Rubber antivibration mounts 2x UATYAAVM1 1x UATYAAVM1 + 1x UATYAAVM2 2x UATYAAVM1 + 1x UATYAAVM2 4x UATYAAVM1 2x UATYAAVM1 + 2x UATYAAVM2 Rainproof hood with anti-intrusion\u003c\/p\u003e\u003cp\u003egrille Control UATYACO2P - Duct air quality CO2 probe UATYACAP - Constant air pressure control airflow transducer UATYAWRC - Remote touch screen wired remote controller UATYARRP - Room temperature return probe (incl. housing) UATYASA - Fire and smoke detector Other Rubber anti vibration mounts Rainproof hood with anti-intrusion grille PDF Data:\u003c\/p\u003e\u003ch3\u003eKey Details\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eBrand \/ Vendor: Daikin Air Conditioning\u003c\/li\u003e\n\u003cli\u003eProduct SKU: UATYA-BBAY1-14742\u003c\/li\u003e\n\u003cli\u003eMPN \/ Model: UATYA70BBAY1\u003c\/li\u003e\n\u003cli\u003eCategory: Daikin Air Conditioning Rooftop Packaged UATYA-BBAY1 Heat Pump Base Model\u003c\/li\u003e\n\u003cli\u003eParent Category: Daikin Air Conditioning Rooftop Packaged Units (Heat Pumps)\u003c\/li\u003e\n\u003cli\u003eCondition: New\u003c\/li\u003e\n\u003cli\u003eAvailability: InStock\u003c\/li\u003e\n\u003cli\u003eTieDex UK\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Daikin Air Conditioning","offers":[{"title":"Default Title","offer_id":56306323980667,"sku":"UATYA-BBAY1-14742","price":36514.74,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0283\/5408\/4963\/files\/daikin-air-conditioning-rooftop-packaged-uatya70bbay1-heat-pump-70kw-238000btu-415v-50hz-14742-p.jpg?v=1782055887","url":"https:\/\/tiedex.co.uk\/fr\/products\/daikin-air-conditioning-rooftop-packaged-uatya70bbay1-heat-pump-70kw-238000btu-415v-50hz-14742","provider":"TieDex","version":"1.0","type":"link"}