Samsung Air Conditioning Samsung EHS AE050RXYDEG/EU ACL-150PSW Slim Line Pre-Plumbed DHW Cylinder 150L 30L Buffer 5Kw 1Ph
Samsung Air Conditioning Samsung EHS AE050RXYDEG/EU ACL-150PSW Slim Line Pre-Plumbed DHW Cylinder 150L 30L Buffer 5Kw 1Ph is listed for TieDex store sale under Solar / Heat pump Compatible Hot Water Cylinders. The brand/vendor is Samsung Air Conditioning. This listing has been prepared with structured product information, clean import fields, image mapping, and SEO-ready content for online selling.
Product Overview
This Kit Includes: • 1 × Samsung EHS Monobloc Air-to-Water Heat Pump Outdoor Unit AE050RXYDEG/EU (5kW, 1 Phase, R32) • 1 × Samsung Slim Line Pre-Plumbed DHW Cylinder ACL-150PSW (150L cylinder with 30L buffer) • G3 Compliance Kit (including expansion vessel, cold water group set and tundish) • Pre-installed plumbing and key hydronic components within the cylinder package • Installation and user documentation • Includes MIM-E03CN (1-zone) control , with optional control kit MIM-E03FN (2-zone) which can be selected on this webpage if required for zoning/control preference Efficient Hot Water + Space Heating Package for Compact Plant Rooms This Samsung EHS package combines a 5kW R32 monobloc air-to-water heat pump with a slimline, pre-plumbed domestic hot water cylinder and integrated buffer tank — ideal for projects where you want a cleaner install, reduced on-site labour, and a tidy mechanical layout.
The AE050RXYDEG/EU outdoor unit is designed for stable, energy-efficient low-temperature heating performance, while still supporting higher leaving water temperatures up to 65°C. Paired with the ACL-150PSW pre plumber tank, you get a practical DHW solution with a 150L cylinder plus 30L buffer, helping improve system stability and supporting consistent heat pump operation, particularly during demand changes. With a strong coil rating and pre-integrated safety and system components, this is a great fit for residential applications, new builds, and light commercial properties where plant space is limited but performance and a professional finish still matter. Key Product Features: • Monobloc air-to-water inverter heat pump using lower-GWP R32 refrigerant • Slimline pre-plumbed DHW cylinder with integrated 30L buffer for improved system stability • High coil performance for fast hot water recovery • Designed for streamlined installation with key hydronic components already integrated
• Suitable for heating and domestic hot water in compact plant rooms • Supports leaving water temperatures up to 65°C (heating) • Strong seasonal performance figures for MCS-aligned planning and specification work • Control kit can be chosen to suit the site setup (single zone or two zone, if required) Technical Specifications: Heat Pump Outdoor Unit (AE050RXYDEG/EU) Heating Temperature Range: 15°C to 65°C MCS Listed SCOPs: @ 35°C: 4.46 @ 40°C: 3.56 @ 45°C: 3.65 @ 50°C: 3.35 @ 55°C: 3.05 Sound Power Level: 61 dB(A) Minimum Flow Rate: 7 Maximum Flow Rate: 48 Refrigerant: R32 Refrigerant Charge: 1.0 kg Dimensions (H × W × D): 798 × 880 × 310 mm Weight: 58.5 kg Power Supply: 1 Phase, 220–240V, 50Hz Slim Line Pre-Plumbed DHW Cylinder (ACL-150PSW) Cylinder / Buffer Capacity: 150L / 30L Usable Water Volume (V40): 230L Actual
DHW Volume: 134L Height: 1898 mm Diameter: 475 mm Empty Weight: 75 kg Full Weight: 214 kg Coil Size: 1.8 m² Coil Rating: 26.6 kW Standing Heat Loss: 1.64 kW/24h (68 W) Energy Efficiency Class: C Booster Heater: 3kW @ 230V AC DHW Expansion Vessel: 12L Primary PWM Circulating Pump: Wilo Para 7-50/iPWM 3-Port Diverter Valve (28mm): Honeywell V4044C1288 Additional Integrated Items: Sika flow meter, magnetic filter (multi-layer mesh), DHW temperature sensor, filling loop and fill/flush point Quick Zone Controller Difference: MIM-E03CN (1-zone) vs MIM-E03FN (2-zone): MIM-E03CN (1-zone): Designed to control one heating circuit (one target flow temperature / one schedule). Typically used for a single system type, e.g. radiators only or underfloor only. Usually supplied with a standard wired controller (referenced with MWR-WW10N). MIM-E03FN (2-zone): Designed to control two independent heating circuits, each with its own control logic and
schedule (commonly radiators + underfloor heating). This is the one that typically includes a larger touch controller and Wi-Fi capability, making it better for mixed applications and more detailed control. MIM-E03CN (1-zone) Included Parts: MWR-WW10N wired controller Flow sensor Main PCB + mounting box Leaving + return water sensors DHW temperature sensor MIM-E03FN (2-zone / “AI Home” style control) Included Parts: 7” colour touchscreen “AI Home” panel MWR-WW10N wired controller Extra sensors (DHW / mixing valve / electric heater sensors) PV control cable Flow sensor assembly (with pipe/fittings) Disclaimer: Specifications may be subject to change based on manufacturer updates. Images are for illustrative purposes only.
Key Details
- Brand / Vendor: Samsung Air Conditioning
- Product SKU: AE050RXYDEG/EU ACL-150PSW
- MPN / Model: AE050RXYDEG/EU ACL-150PSW
- Category: Solar / Heat pump Compatible Hot Water Cylinders
- Parent Category: Air To Water Heat-pump
- Condition: New
- Availability: InStock
- TieDex UK